180° or 270° bracket swivel range,
Note the following points when welding:
- Welding must be carried out by an approved welder in line with EN-287-1.
- Base plate material must be St 52-3 (1.0570)
- Before welding ensure that the surface to be welded is thoroughly clean and free of moisture, dirt, oil, paint and scale.
- Ensure there is no contact between the red bracket and weld metal.
- The assembly can be annealed several times at 600°C without reducing the load capacity.
- Welding components must be suitable for force distribution.
- Spacers provide clearance for the necessary air gap for foot welding ( approx. 3mm)
During welding (permanent HV), ensure the following as required by DIN 18000 steel structures:
For external points or special corrosion risk, welding seams should be continuous fillet welds. The HV
weld seam on the LBS ensures connection across the entire material face, so that the fully enclosed
seam prevents corrosion.
DOWNLOAD:
Brochure
User instructions
Lifting point Load capacity table:
Sling type | ||||||||
---|---|---|---|---|---|---|---|---|
Inclination angle | 0° | 90° | 0° | 90° | 0°-45° | 46°-60° | 0°-45° | 46°-60° |
Type | Load capacity t | |||||||
CM08WLP-01 | 1,60 | 1,12 | 3,20 | 2,24 | 1,50 | 1,12 | 2,36 | 1,60 |
CM08WLP-02 | 3,00 | 2,00 | 6,00 | 4,00 | 2,80 | 2,00 | 4,00 | 3,00 |
CM08WLP-03 | 4,75 | 3,15 | 9,50 | 6,30 | 4,25 | 3,15 | 6,30 | 4,75 |
CM08WLP-05 | 8,00 | 5,30 | 16,00 | 10,60 | 7,10 | 5,30 | 11,20 | 8,00 |
CM08WLP-08 | 12,00 | 8,00 | 24,00 | 16,00 | 11,20 | 8,00 | 16,00 | 12,00 |
CM08WLP-15 | 22,40 | 15,00 | 45,00 | 30,00 | 21,20 | 15,00 | 31,50 | 22,40 |
For asymmetrical load distribution for the 2- and 3/4-strand chain slings, the load capacities for 1 strand at 90° apply. For welding instructions see the operating instructions!
Loading of the bracket transverse to the swivel level is permitted but should not be provided as standard load direction!